High Temperature Thermocouple

  • Resistance to high temperature and high pressure thermocouple
Resistance to high temperature and high pressure thermocouple

Resistance to high temperature and high pressure thermocouple

  • high pressure thermocouple
  • Product description: Resistance to high temperature and high pressure thermocouple is suitable for the temperature measurement and control of high temperature and high pressure places in the production process of petroleu
  • INQUIRY

Resistance to high temperature and high pressure thermocouple is suitable for the temperature measurement and control of high temperature and high pressure places in the production process of petroleum and chemical industry.high temperature thermocouple is an indispensable temperature device for refineries and high pressure polyethylene.

2. Main technical parameters 

electrical outlet: M20x1.5, NPT1 / 2 connection 

size: M20x1.5, NPT1 / 2 

Protection grade: IP65 

Explosion proof grade: d∥BT4, d∥CT5 

Nominal pressure: 15-40MPa 

3, Model and specification

Model

Indexing number

Temperature measurement range

Thermal response time

Protective tube material

Specification Lxl

WRNG-430 WRN2G-430

K

0-800

< 180S

1Cr18Ni9Ti

380x150 430x200 480x250 530x300 580x350 630x400 680x450

WREG-430 WRE2G-430

E

0-600

WRNG-440 WRN2G-440

K

0-800

WREG-440 WRE2G-440

E

0-600

1) Thermocouple class I shall be ordered according to the agreement; 

2) other materials of protective tube shall be ordered according to the agreement; 

3) Model 430 is waterproof and model 440 is explosion-proof.

4. Material and selection of protection pipe

Texture of material

Operating temperature

Features and uses

1Cr18Ni9Ti

-200 - 800

High temperature corrosion resistance, usually used for general heat-resistant steel

304

-200 - 800

Low carbon content, good intergranular corrosion resistance, usually used as general heat-resistant steel

316

-200 - 750

Low carbon content, good intergranular resistance, usually used as heat-resistant steel

316L

-200 - 750

Ultra low carbon content, good intergranular corrosion resistance, usually used as heat-resistant steel

310S

-200 1000

High temperature oxidation resistance, corrosion resistance, usually used as heat-resistant steel

GH3030

0 - 1100

Nickel base superalloy steel, with excellent oxidation resistance and corrosion resistance, is usually used as heat-resistant steel

5.Protection Tube type selection

Resistance to high temperature and high pressure thermocouple

6. flange model and specification
Flange standard code

Standard code

Document No

China National Standard

GB9112-9131-88

Standard of Ministry of chemical industry of China

HG20592-20635-97 ( HGJ44-76-91 ) ( HG5001-5028-58 )

Standard of China Ministry of machinery

JB/T74-90-94 ( JB81-82-59 )

American Standard

ASME/ANSI B16 . 5-88

German standard

DIN 2628-2638-1975

Japanese standard

JIS2201-1796

7,Flange specification

Class150-600 RF 

class900-2500 RJ 

8,Notices in Type Selection

1) model 

2) graduation 

3) accuracy grade 

4) material and form of protection tube 

5) flange specification and form 

6) length or insertion depth 

example a: high temperature and high pressure flame-proof thermocouple K type 1 protection tube a type insertion depth 300 mm. Wrng-440a L × 1 = 450 × 300 mm. D Ⅱ BT4 316L ANSI 1 ″ 1500 RJ

 


Scan the qr codeClose